Data Center : Singapore IBX Center
IP Test Ping : 45.42.143.98
Data Center Address : 20 Ayer Rajah Crescent Ayer Rajah Industrial Park 139964, Singapore
Located within a 9-story building in Ayer Rajah Industrial Park.
Raised 208 psf floor with a 10 to 12.5 kN/m2 floor load.
4.9m slab-to-ceiling height.
Access to 210 network carriers for unmatched customer reach.
MAS Compliant.
Offers access to a fully equipped Solution Validation Center.
Power Systems
1.2 – 4kVA electrical capacity.
2 x 22kV Power Utility Feeders.
10 x 3 MVA (N+1) Power Transformers.
2N UPS Configuration.
2N UPS Redundancy.
8 x 1,375 kVA and 3 x 2,000 kVA standby diesel generators.
N+1 Standby Power Redundancy.
Temperature Control
1.2 – 4kVA cooling capacity per cabinet.
Air-Cooled Centrifugal Chillers – 3 x 300 RT + 5 x 350 RT (N+1).
Water-Cooled Centrifugal Chillers – 4 x 600 RT + 1 x 300 RT (N+1).
Computer Room Air Conditioners – N+25%.
Cooling redundancy of N+1 (on chillers) and N+25% (on CRAC units).
VIEW, VESDA, and FM-200 fire suppression systems.
Pre-action dry pipe sprinklers.
Building Security
24/7 onsite security officers.
Man-trap entry.
Biometric readers in common areas.
A combination of biometrics, PIN, and Card readers in sensitive areas.
CCTV surveillance with a 30-day retention.
Motion detection alarm system.
Network
Cat5e/6, COAX and Fiber cross-connects.
Fast Ethernet, Gigabit Ethernet, and 10Gigabit Ethernet.
High-speed fiber connectivity extends choice and reach for carrier and network availability.
Central switch for public and private peering.
Automated network provisioning, multi-homing, and billing.
Data Center : LA Telecom Center
IP Test Ping : 66.248.240.55
Data Center Address : 530 West 6th Street Los Angeles, California
163,600 square foot building fully dedicated to data center services.
Direct conduit of less than 500 feet connectivity to One Wilshire.
Complete renovation conducted in 1998.
24/7 on-site engineers to support building systems and provide client service.
Power Systems
6000 amps, 277/480 Volt, 3-phase, and 4-wire electrical service.
Each suite equipped with 2 x 150KvA UPS Battery Backup Units.
Redundant UPS ensures 30 minutes of battery life at full capacity until generators can take over.
1200Amps 480v Input Power per suite.
All suites backed by 3 x 2000Kw Caterpillar Generators.
Generators have separate diesel tanks with refuel contracts.
Temperature Control
Liebert System 3 HVAC Units.
Data center floor temperature at 65 ° F more or less 2 ° F.
Dry pipe fire suppression with pre-activation.
500 Ton redundant HVAC central plant, consisting of two-250 Ton Cooling Towers.
Building Security
24/7 manned security with regular patrols from LAPD.
Biometric palm scan authentication access requirement.
Substantial amount of surveillance cameras with offsite backup.
Every suite secured by keycard authorized entry
Guests are required to have background check and be accompanied by onsite staff
Network
Redundant Brocade XMR 4000 Edge Routing.
Full router redundancy – 3 switch fabrics, multiple line-cards, 2x management modules.
Cisco Catalyst Distribution Switches (N+1 redundant).
Cisco Catalyst 2950 and 3750 access switches (redundancy).
Connections to the One Wilshire “meet me Room” are provided through the second floor Network Access Center (NAC).
Data Ceter : Westin Building Exchange
IP Test Ping : 45.42.142.1
Data Center Address : 2001 6th Ave Suite #400 Seattle, WA 98121
Facility is Designed With 2N Redundancy.
400,000 SF (sq ft) Gross – Data Center Space.
Hub of the Pacific Northwest.
Tier 4 Rated Data Center.
Built to Seismic Zone 3 Standards.
Typical structural capacity of 150 lbs/SF or 1500 lb cabinets.
Power Systems
Multiple 13.5 kV feeds.
Multiple transformer vaults – 480V 3 Phase.
2N redundancy facility wide.
Canara battery monitoring system.
17 diesel generators, totaling 19.5 MW.
Redundant AC/DC UPS power.
Temperature Control
Five diverse cooling towers.
N+1 redundancy on all cooling systems.
Onsite reserve water tanks.
Hot/Cold aisle design with raise floors.
Building Security
24×7 onsite dedicated security staff.
24×7 secure/monitored site access.
CCTV monitoring and recording.
Individual locking cabinets for Colocation clients.
Sign in and identification required.
Network
Carrier Neutral Facility with more than 200 carriers.
Diverse Premier Fiber and Copper Meet-Me Rooms.
Multiple fully diverse underground main points of entry.
Fully redundant network with no single point of failure.
Low latency and high throughput network across
North America, Asian and Europe countries.
Data Center : Pulsant Data Center
IP Test Ping : 78.157.209.195
Data Center Address : West Park Ind Est 211 Torrington Avenue Coventry, UK CV4 9HN
2 story building, raised floors, hot/cold aisles.
4500sq/ft of privately owned rack space.
Concrete, brick, and steel.
Sits right on main backbones in UK.
Privately Owned Suite in DC.
SAS 70 compliant.
Power Systems
Two redundant high voltage power systems, from separate power grids.
2 x 2.5MVA 11kV Generators.
Two redundant UPS, floor by floor with battery backup.
A + B power to individual servers upon request.
Generators have separate diesel tanks stored in basement.
Temperature Control
Latest technology n+1 evaporative cooling system.
850mm raised floor design to provide the most efficient cooling.
Hot aisle/cold aisle zone design.
Free cooling operation in winter.
2 x 2.7MW chillers.
Room Air Conditioning Units provide a down stream chilled water system.
Building Security
Swipe identification card & visual entry check by manned security.
Keycard access and video facial recognition surveillance.
Monitoring and secure single-person point of entry, which is physically guarded 24/7 and the
presence of integrated surveillance.
Full Interior and Exterior CCTV Coverage and Recording.
Network
100Gbps onsite connectivity.
Diverse fiber backhaul to docklands.
Multiple ranges of fiber providers sitting miles from DC.
Premium Cisco hardware with redundant topology.
Automatic DDoS detection and mitigation systems to avoid any disruption in service.
Partnering with INAP Our carrier-neutral, SOC 2 Type II facilities are concurrently maintainable, energy efficient and support high-power density environments of 20+ kW per rack. INAP’s robust global network presence, comprehensive Connectivity Solutions suite, and route-optimized, low-latency, Performance IP® service, helps us deliver the network performance you demand.
IP Test Ping : 64.74.200.107
Security & Access:
Key card access with secondary biometric authentication
Video surveillance with a minimum of 90-days video retention
24/7/365 onsite personnel
Power Systems:
Fully integrated critical infrastructure monitoring
14.8 MW of power capacity
N+1 with concurrent maintainability
Network:
Carrier-neutral connectivity to multiple providers
Performance IP® mix for patented traffic route optimization
Geographic redundancy
Facility:
4,205 tons of cooling capacity
Over 200,000 square feet of leased space with
45,000 square feet of raised floor
High-density configurations available
PCI DSS, HIPAA, SOC 2 Type II, Green Globes and ENERGY STAR